1.1 This practice covers only S-N and ε–N relationships that may be reasonably approximated by a straight line (on appropriate coordinates) for a specific interval of stress or strain. It presents elementary procedures that presently reflect good practice in modeling and analysis. However, because the actual S-N or ε–N relationship is approximated by a straight line only within a specific interval of stress or strain, and because the actual fatigue life distribution is unknown, it is not recommended that (a) the S-N or ε–N curve be extrapolated outside the interval of testing, or (b) the fatigue life at a specific stress or strain amplitude be estimated below approximately the fifth percentile (P ≃ 0.05). As alternative fatigue models and statistical analyses are continually being developed, later revisions of this practice may subsequently present analyses that permit more complete interpretation of S-N and ε–N data.
![ASTM E739-10 ASTM E739-10 pdf](https://www.sustandard.com/wp-content/uploads/2025/01/1755724.jpg)
ASTM E739-10
Original price was: $60.00.$30.00Current price is: $30.00.
Standard Practice for Statistical Analysis of Linear or Linearized Stress-Life (S-N) and Strain-Life (Epsilon-N) Fatigue Data
ASTM International , 11/01/2010